Slurry Pumps FRT series
It is suitable to pump both bovine and pig slurry and it could be installed on fixed equipment and self-propelled sprinklers, where medium/high heads are required.
The pump is outfit of a oil-bath gear multiplier, with impeller shaft supported by roller-type cone-shaped bearing; electrowelded support and suction structure; spheroidal cast iron hydraulic unit. The shaft rotor has the chromium-plated seal only in the working area; the seal is of lubricated mechanic and rotating type. 6-paddled open impeller. The NTC series has also been designed to be installed on endothermic motors.
![]() |
|||
| NT 100 E 6-paddled open impeller Nominal power range from: 50 to 100 Hp - 37 to 75 KW | |||
|---|---|---|---|
| Impeller revs. revs.min. | Capacity Lt/min. | Prevalence Mt. | Absorbed Power KW |
| 3.200 | 800 1.000 1.200 1.400 1.600 1.800 2.000 |
71 70 69 67 66 65 64 |
26 28 30 32 34 36 40 |
| 3.500 | 800 1.000 1.200 1.400 1.600 1.800 2.000 |
33 35 37 40 42 45 48,5 |
86 85 83 81 80 79 77 |
| 3.800 | 800 1.000 1.200 1.400 1.600 1.800 2.000 |
42 44 47 51 54 57 60 |
102 100 98 96 95 94 92 |
![]() |
|||
| NT 125 E 6-paddled open impellerNominal power range from: 80 to 130 Hp - 60 to 95 KW | |||
|---|---|---|---|
| Impeller revs. revs.min. | Capacity Lt/min. | Prevalence Mt. | Absorbed Power KW |
| 2.500 | 1.000 1.250 1.500 1.750 2.000 2.250 2.500 |
65 63 62 61 60 59 58 |
28 29 33 35 37 39 42 |
| 2.700 | 1.000 1.250 1.500 1.750 2.000 2.250 2.500 |
77 76 75 73 72 71 70 |
33 36 39 41 44 47 49 |
| 2.900 | 1.000 1.250 1.500 1.750 2.000 2.250 2.500 |
90 89 88 86 85 84 83 |
43 46 50 54 57 59 62,5 |
![]() |
|||
| FRT 94/35 6-paddled open impellerNominal power range from: 80 to 150 Hp - 60 to 110 KW | |||
|---|---|---|---|
| Impeller revs. revs.min. | Capacity Lt/min. | Prevalence Mt. | Absorbed Power KW |
| 2.000 | 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.250 |
87 83 80 77 75 73 67 58 |
36 41 48 50 52 53 57 61 |
| 2.500 | 1.500 1.750 2.000 2.250 2.500 2.750 3.000 3.250 |
141 138 135 134 128 126 125 120 |
59 69 75 79 88 92 98 103 |
Slurry pumps FRT K series outfit of shredder
Suitable to pump slurry, particularly the bovine one. It is used on fixed equipment and self-propelled sprinklers, where medium/high heads are required; the shredder is also provided.
![]() |
|||
| NT 100 E K 6-paddled open impeller Nominal power range from: 65 to 110 Hp - 50 to 80 KW | |||
|---|---|---|---|
| Impeller revs. revs.min. | Capacity Lt/min. | Prevalence Mt. | Absorbed Power KW |
| 3.200 | 800 1.000 1.200 1.400 1.600 1.800 2.000 |
70 69 68 66 65 63 60 |
34 36 38 41 43 45 45 |
| 3.500 | 800 1.000 1.200 1.400 1.600 1.800 2.000 |
85 83 81 80 78 77 75 |
44 46 49 51 53 55 54 |
| 3.800 | 800 1.000 1.200 1.400 1.600 1.800 2.000 |
101 99 97 95 92 91 89 |
56 59 61 64 67 69 62 |
![]() |
|||
| NT 125 E K 6-paddled open impeller. Nominal power range from: 80 to 130 Hp - 60 to 95 KW | |||
|---|---|---|---|
| Impeller revs. revs.min. | Capacity Lt/min. | Prevalence Mt. | Absorbed Power KW |
| 2.500 | 1.000 1.250 1.500 1.750 2.000 2.250 2.500 |
62 61 59 58 57 56 55 |
33 36,5 39 41 44 46 47,5 |
| 2.700 | 1.000 1.250 1.500 1.750 2.000 2.250 2.500 |
74 72 71 70 69 68 66 |
44 47 51 53 55 57 61 |
| 2.900 | 1.000 1.250 1.500 1.750 2.000 2.250 2.500 |
87 86 85 83 81 80 80 |
54 56,5 60 62 64 68 72 |
![]() |
|||
| FRT 94/40 K 3-paddled open impeller. Nominal power range from: 80 to 150 Hp - 60 to 110 KW | |||
|---|---|---|---|
| Impeller revs. revs.min. | Capacity Lt/min. | Prevalence Mt. | Absorbed Power KW |
| 2.000 | 1.500 1.750 2.000 2.250 2.500 2.750 3.000 |
73 71 69 65 61 57 51 |
34 37 40 43 47 52 55 |
| 2.500 | 1.500 1.750 2.000 2.250 2.500 2.750 3.000 |
118 117 116 112 108 104 95 |
58 64 70 74 79 87 94 |
DATA OBTAINED FROM TESTS CARRIED OUT IN WATER BY THE MACHINE LABORATORY OF THE ENGINEERING FACULTY OF BOLOGNA UNIVERSITY